
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 7 - Jul 12
For Your Every Summer RSVP, with Code: SUMMER15
Description
Human GSK3b ELISA KitProduct Specification Usage Required experimental equipment: 1. Microplate reader (450nm) 2. High precision pipettes and pipette tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre chilled PBS (0. 01M, pH 7. 4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and
Product Specification
| Usage | Required experimental equipment: 1. Microplate reader (450nm) 2. High-precision pipettes and pipette tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37°C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and mince the tissue. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000×g for 5-10 minutes, and collect the supernatant for analysis. Cell Lysis Buffer: Gently wash adherent cells with pre-chilled PBS, then trypsinize and collect the cells by centrifugation at 1000×g for 5 minutes. Suspension cells can be collected directly by centrifugation. Wash the collected cells three times with pre-chilled PBS and resuspend in 150-200 μL of PBS per 1×10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately). Disrupt the cells by repeated freezing and thawing or sonication. Centrifuge the extract at 1500×g for 10 minutes at 2-8°C, and collect the supernatant for analysis. Cell Culture Supernatant: Centrifuge at 1000×g for 20 minutes. Collect the supernatant for analysis, or store at -20°C or -80°C, but avoid repeated freezing and thawing. Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test. Pre-test preparation: 1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 20 ng/mL). Then dilute to the following concentrations: 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, and 0 ng/mL. Serial dilution method: Take 7 EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 20 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 10 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves directly as a blank well; there is no need to aspirate the liquid from the penultimate tube. See the figure below for details. 3. Preparation of Biotinylated Antibody Working Solution: 15 minutes before use, centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration using universal diluent (e.g., 10µL concentrate + 990µL universal diluent). Prepare immediately before use. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a capture antibody against Glycogen Synthase Kinase 3 Beta (GSK3b). After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of Glycogen Synthase Kinase 3 Beta (GSK3b) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Human | |||||||||||||||||||||||||||||||||
| Synonym | Human Glycogen Synthase Kinase 3 Beta ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Glycogen synthase kinase 3β (GSK3β), encoded by the GSK3β gene, is an evolutionarily conserved serine/threonine kinase ubiquitously present in mammalian eukaryotic cells. In addition to its earliest known role in regulating glycogen synthase (GS) activity, it also acts on numerous signaling proteins, structural proteins, and transcription factors to regulate cell differentiation, proliferation, survival, and apoptosis. It has been selected as a therapeutic target in the research of a variety of major diseases, including cancer, neurodegenerative diseases, and neuropsychiatric disorders. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.312-20 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Tissue homogenates, cell lysates, cell culture supernatants, and other biological fluids |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.0 ★★★★★
Based on 1122 reviews
Sort
Product Reviews
★★★★★ 5
Filter quality and value
Style: CF11809 Classic
2nd time to purchase this item over a 5 year period. The filter has a rigid frame making last much longer than other paper filters. Perfect fit and worth the cost. Great job filtering cabin and neutralizing odors!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 19, 2026
★★★★★ 5
Simple Upgrade That Makes a Real Difference
Style: CF10140 Classic
Installed the Zezut cabin filter in my 2005 Infiniti G35 and noticed the difference immediately. The air inside the car felt fresher and cleaner right away — no more stale air circulating through the vents. The HEPA backing is a big deal, knowing it's actually filtering out dust, pollen, and particles rather than just being a basic filter gives you real peace of mind. The quality feels solid and well made. Installation was super easy, took just a few minutes with no tools needed. For the price this is one of those simple maintenance upgrades that's absolutely worth doing. Your lungs will thank you. Great price and affordable, top choice for replacement in my opinion.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 27, 2026
★★★★★ 4
Good filter.
Great filter works well .
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 12, 2026
★★★★★ 5
Efficient long lasting. Great Value
Style: CF10735 Classic
These filters (my second one) has lasted me over two years with a little maintenance in between, (removing from time to time to vacuum and shake out the bigger debris.) They do a great job of keeping the cabin air really clean and fresh.
1) Over designed and built (Good thing) installed without effort.
2) Fit and finish is perfect for my 2016 Genesis G80
3) Carbon filter works well but after about six months it no longer absorbs orders, This is excepted especially when I have not swapped it out for over two years.
4) Great value and honestly I should be replacing these cabin filters out ever six months for efficiency and order control.
Note: When I decided to replace it the filter held up structurally as the day I installed it. The charcoal beads where all intact as well.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 30, 2026
★★★★★ 5
Better than OEM, AC is so fresh now!
Style: CF10374 Classic, Style: CF10374 Classic
YEEEEEEAHHHHH!
This went straight from the mailman's hand to my 2010 Tacoma.
-Fits better than OEM and Replacements!
-AC smells so fresh now!
-Easy installation without any complications.
-Has a foam gasket around the filter that makes it fit like a glove, thight and secure!
-Very Well Made and quality materials.
Won't be returning this one, will actually buy it for the rest of my cars!
⭐️⭐️⭐️⭐️⭐️
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 11, 2026